Capacity Air Conditioner 1.0 HP | Type | Refrigerant Gas R32 |
Specifications | ||
Made in | : | Brand: Japan - Made in: Thailand |
Refrigerant | : | R32 |
Type | : | Inverter - 1-way type (cooling only) |
Cooling Capacity | : | 1.0 Hp - 9.554 Btu/h |
Use For Room | : | Area 12 - 15 m² or 36 - 45 m³ |
Power Input (Ph/V/Hz) | : | 1 Phase, 220-240V, 50Hz/60Hz |
Power consumption (kW) | : | 0.69 kW |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 6.35 / 9.52 |
Maximum Pipe Length | : | 20 m |
Maximum Elevation Length | : | 10 m |
Energy Efficiency Level | : | 5 star |
Indoor Unit | ||
Indoor Unit Model | : | SRK10YXS-W |
Indoor Unit Dimensions (mm) | : | 290 x 870 x 230 mm |
Indoor Unit Net Weight (Kg) | : | 10 Kg |
Outdoor Unit | ||
Outdoor Unit Model | : | SRC10YXS-W |
Outdoor Unit Dimensions (mm) | : | 540 x 645 x 275 mm |
Outdoor Unit Net Weight (Kg) | : | 27 Kg |
The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.
Power blackout auto restart function is a function that records the operational status of the air-conditioner immediately prior to it being switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.
If the remote control fails, the unit can be operated via an on/off switch on the indoor unit.
An inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputscan ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner canslow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motordriven so it provides higher performance.
With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate all desired functions of the unit with the click of a button.
In the case that the air conditioner malfunctions, an internal microcomputer automatically runs a self-diagnosis. (Inspection and repair should be performed by authorized dealers.)
The blower fan has undergone anti-microbial to resist mold and germs, maiking the system clean and safe. Foul odors and molds, etc. Which can occur when an air conditioning system is not in operation are prevented.
The air inlet panel on the indoor unit opens the closes easily, making filter cleaning simple. The suction panel can also de removed.
Enzymes used in the filter are naturally occurring lytics enzymes which attack cell walls of micro-organisms trapped on the filter and destroy them.
Deodorizing Filter It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing to the sunlight.
Self clean mode dries the indoor unit and filter, preventing the growth of mould. This runs for 2 hours after the unit has been switched off.
By combining a start timer with a stop timer, you can register two timer operations a day. Once set, timers will faithfully start or stop the system at a specified time of the day repeatedly.
Blocks the unit preventing tampering and inadvertent operations. This function is useful for families with young childen.
In ON-TIMER operation, the unit automatically starts the operation a little earlier, so that the room can approach optimum temperature at ON time.
DRY The unit dehumidifies the room by intermittent cooling operation.
The unit can operate continuously in "HI POWER" mode for 15 minutes. This mode is convenient to reach the desired temperature Auto quickly.
Brightness of the LED display can be adjusted to suit.
This timer allows the unit to be set to turn ON or OFF automatically once within a 24 hour period.
You can set the left-right air flow directions when you installed the air conditioner near the side wall by remote controller operation.
The desired preset operation mode can be enabled with a single touch of a button.
The sound level of outdoor units is at least 3 dB(A) lower than the nominal level.
The room temperature is automatically controlled during the set sleep mode period, ensuring that room temperature will not get too cold or too hot.
Up to 4 programs with timer operation (ONTIMER/ OFF-TIMER) are available for each day of the week. MAX 28 programs per week can be set.
The unit will operate in energy saving mode in order to avoid excessive heating and cooling.
This one touch program will activate the three independent motors to evenly distribute air flow and create optimum heating and cooling conditions.
Depending on the operating mode, the unit will automatically set the position of the louvers at the optimal angle.
Aircraft technology is used to component design the air flow system of the air conditioner.
With our remakable jet flow technology, its allows at one long reach air flow (18m) and minimum power consumption.Aircraft technology is used to component design the air flow system of the air conditioner.
While the louver is swinging it can be stopped at any angle. On the next start-up the louver returns to the same positron that it was when the operation last stopped.
Louver moves right and left continuously. The Right/Left louver swing can be fixed at the preferred operation angle.
Flap moves up and down continuously. The Up/Down flap swing can be fixed at the preferred operation angle.