Capacity Air Conditioner 2.5 HP | Type | Refrigerant Gas R32 |
Specifications | ||
Made in | : | Brand: Japan - Made in: Vietnam |
Refrigerant | : | R32 |
Type | : | Inverter (tiết kiệm điện) - loại 1 chiều (chỉ làm lạnh)Inverter - 1-way type (cooling only) |
Cooling Capacity | : | 2.5 Hp (2.5 HP) - 20.500 Btu/h |
Use For Room | : | Area 31 - 35 m² or 93 - 105 m³ (suitable for living room, office). |
Power Input (Ph/V/Hz) | : | 1 Pha, 220 - 240 V, 50Hz |
Power consumption (kW) | : | 2.06 kW |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 6.4 / 12.7 |
Maximum Pipe Length | : | 30 m |
Maximum Elevation Length | : | 20 m |
Cooling Seasonal Performance Factor (CSPF) | : | 4.90 |
Energy Efficiency Level | : | 5 start |
Indoor Unit | ||
Indoor Unit Model | : | FTKA60UAVMV |
Indoor Unit Dimensions (mm) | : | 285 x 770 x 226 mm |
Indoor Unit Net Weight (Kg) | : | 8 kg |
Outdoor Unit | ||
Outdoor Unit Model | : | RKA60UVMV |
Outdoor Unit Dimensions (mm) | : | 595 x 845 x 300 mm |
Outdoor Unit Net Weight (Kg) | : | 35 kg |
Unique design of Coanda panel brings the airflow along the ceiling, to spread out across the whole room without creating uncomfortable drafts directly o the body, bring maximum comfort
This design applies from the scientific Coanda phenomenon, causing the cold air emanating from the mouth of the wind to be pushed up to the ceiling and then gently radiate down, covering the entire room.
This delicate design helps the Daikin air conditioner bring comfort to users, do not blowing air directly into the area, but distributing fresh air evenly throughout the room for all users in the room.
This feature includes a high-strength electronic circuit installed in the outdoor unit.
When the voltage fluctuates abnormally, this circuit protects the fan motor and compressor without the need to install a voltage stabilizer.
Specifically, in the voltage range from 150-264V: the machine works normally. Over 264-440V: the air conditioner will stop by itself, disconnect the power to prevent damage.
Notes: applied with 1 phase electricity
The outdoor unit’s heat exchanger fins are processed using a special anti-corrosion treatment: coated with two electrostatic coatings, the surface is covered with a thin acrylic resin layer to provide enhanced resistance to acid rain and salt corrosion.
When the indoor air conditioner turns on, the outdoor air conditioner outdoor unit will experience weather conditions such as hot sunlight, stormy rain, or sea breeze causing the radiator to corrodes and destroy.
A conventional aluminum radiator is covered with zinc to protect the aluminum material inside. However, the aluminum cover can still corrode.
With a larger heat exchanger area and higher airflow volume compared to conventional oness, the Microchannel heat exchanger helps higher heat exchange efficiency. In addition, the durability of the radiator is also proved when it passes the 2,000 hour salt spray test without leaking due to corrosion. (*)
(*) The test is carried out by Daikin Research and Development Center Thailand
An Inverter system of Daikin with swing compressor and DC motor can help to noticeably reduce household electricity bills, particularly compared to Non-inverter models. At the same time, improving the noise level of both outdoor and indoor units helps to keep the machine running smoothly, maintain a stable temperature and achieve optimal capacity.
Deodorizes and catches the allergens, bring the fresh air to your house.
This filter removes PM 2.5, particulate matter which is smaller than 2.5 micrometres (µm).
When cooling operation is stopped, fan-only operation runs automatically for one hour. This airflow dries the inside of the indoor unit to prevent the generation of mould and odours, strengthen durability of air conditioner.
Note: The above values are based on operation with 220V, 50Hz.
Measurement conditions
1. Capacity based on: indoor temp. 27 ° CDB, 19 ° CWB; outdoor temperature 35 ° CDB tube length 7.5m.
2. The noise level is based on the above temperature 1 condition, which is an anechoic conversion value. These values may be slightly higher in fortune
actual practice due to the impact of ambient conditions.
3. CSPF is based on TCVN 7830: 2015.
The Power-Airflow Flap flattens out during cooling operation to deliver cool air to the corners of a room. The flap also directs warm air straight down to the floor during heating operation.
This function automatically moves the flaps up and down to distribute air across a room.
The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room.
Unique design of Coanda panel brings the airflow along the ceiling, to spread out across the whole room without creating uncomfortable drafts directly o the body.
Indoor unit operating sound pressure levels are decreased from the Low setting fan speed using the wireless remote controller.
The microprocessor automatically adjusts the fan speed to high to rapidly reach the set temperature. Once the temperature is achieved, this function reduces the fan speed to low.
The computer chip works to rid the room of humidity while keeping the room temperature as stable as possible. It controls the temperature and airflow rate automatically, so manual adjustment of these functions is not available.
The drain pan collects condensation from the indoor heat exchanger fins. Removable drain pans help to reduce the cleaning time and ensure a perfect finish.
The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning
This filter removes PM 2.5, particulate matter which is smaller than 2.5 micrometres (µm).
When cooling operation is stopped, fan-only operation runs automatically for one hour. This airflow dries the inside of the indoor unit to prevent the generation of mould and odours, strengthen durability of air conditioner.
Deodorizes and catches the allergens, bring the fresh air to your house.
Even when an air conditioner is not operating, it requires standby power. However, thanks to this function, the required standby power can be reduced.
This mode limits the maximum power consumption. It improves operating efficiency and also prevents circuit breakers from being overloaded.
This function boosts cooling performance for a 20 minute period. It is convenient when it is necessary to change the room temperature quickly.
To cope with climate change, Daikin has used R-32 - New generation refrigerant, which does not cause ozone depletion and has a low global warming index.
Smartphone control: by adding a WLAN device, you can set the temperature and schedule the air conditioner anywhere, using an Apple or Android ™ device.
The unit can be conveniently started by hand if the wireless remote controller is misplaced or its batteries are not charged.
The operation start and stop times can be set with the touch of a single button and preset for a period of one to 12 hours in one hour increments. When the off timer is set, Night Set Mode is activated automatically.
Pressing the off timer button automatically selects Night Set Mode. This function prevents excessive cooling or heating for a pleasant sleep. After 60 minutes, the room temperature is raised by 0.5˚C for cooling operation or lowered by 2˚C for heating operation.
The air conditioner memorises the settings for operation mode (automatic, cooling, heating, dry and fan only), airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.
Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.
The outdoor unit’s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion.
The product equips with a highly durable electronic circuit that can withstand voltages up to 440V.
(*) FTKA's operating voltage is from 150V-264V. Notes: applied with 1 phase electricity