Capacity Air Conditioner 5.0 HP | Type | Refrigerant Gas R410A |
Specifications | ||
Made in | : | Brand of Japanese, Made in Thailand |
Refrigerant | : | R410A |
Type | : | Inverter AC - Cooling Only |
Cooling Capacity | : | 5.0 HP - 42.700 Btu/h |
Use For Room | : | Room area 64 - 67 m² or Volume 192 - 201 m³ ( Suitable for living room, office ) |
Power Input (Ph/V/Hz) | : | 3 Phase, 380 - 415 V, 50Hz |
Power consumption (kW) | : | 3,77 Kw |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 9.5 / 15.9 |
Maximum Pipe Length | : | 50 (m) |
Maximum Elevation Length | : | 30 (m) |
Cooling Seasonal Performance Factor (CSPF) | : | 5.00 |
Indoor Unit | ||
Indoor Unit Model | : | FCQ125KAVEA |
Indoor Unit Dimensions (mm) | : | 298X840X840 (mm) |
Indoor Unit Net Weight (Kg) | : | 24 (Kg) |
Panel | ||
Panel Dimensions (mm) | : | 50X950X950 (mm) |
Panel Net Weight (Kg) | : | 5.5 (Kg) |
Outdoor Unit | ||
Outdoor Unit Model | : | RZR125MYM |
Outdoor Unit Dimensions (mm) | : | 990X940X320 (mm) |
Outdoor Unit Net Weight (Kg) | : | 73 (Kg) |
Comfortable
Enhanced comfort with Inverter.
Inverter performs variable control of frequency, which determines air conditioner's power performance.
Anti-Corrosion Treatment for Outdoor Unit Heat Exchanger
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
Avoids uneven temperature and discomfort caused by drafts.
Comfort enhanced by Round Flow!
360° airflow
With uniform temperature distribution
Air movement is gentle with Round Flow
Enhanced Comfort
Adapts easily to the installation space.
Because air flows out from corner outlets, comfort spreads more widely.
Note:
Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.
Operation sound increases when using 2-way or 3-way flow.
Grime prevention and bactericidal coating: Make cleaning easier.
External panels are treated with a coating that repels dirt.
Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.
Optimal comfort and convenience assured by 2 air discharge modes
Note:
1. Air direction is set to the standard position when the unit is shipped from the factory. The
position can be changed from the remote controller.
2. Closing of the corner discharge outlets is recommended.
Suitable for high ceilings
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.
When all round flow is selected, ceilings up to 4.2 m in height can be
accommodated. (100-140KA)
Criteria for ceiling height and number of air discharge outlets (Ceiling height is reference value)
Note: Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting.
Two selectable temperature-sensors
Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level.
Use the temperature-sensor in the indoor unit when controlling air conditioning from another room.
Note: Wireless remote controllers have no temperature-sensor.
Switchable fan speed: High/Middle/Low
Control of airflow rate has been improved from 2-step to 3-step
Quick and easy to install
Just 256 mm high. Installable in tight ceiling spaces (50–71KA)
*1 298 mm high with 100–140KA
*2 308 mm high with 100–140KA
Easy height adjustment
Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height.
Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets.
All models can be installed without using lifter because of the light weight.
Installable in any direction
Since the orientation of the intake grill can be adjusted after installing, the direction of the intake grill lines can be unified when multiple units are installed.
Drain pump is equipped as standard accessory with 850 mm lift.
Transparent drain socket
DIII-NET communication standard
Connection to a centralised control system is available without option.
Low gas pressure detection
Insufficient gas charging is normally hard to detect. During test run after installation and regular inspection, the refrigerant level is monitored by a microprocessor to maintain proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly.
Easier to maintain
Options required for specific operating environments
Ultra long-life filter
Even in dusty environments where the air conditioning is on most of the time, the ultra long-life filter only has to be cleaned once a year.
Dusty area: annual filter change
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.)
1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
Ordinary store or office: filter change every 4 years
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 12 month/years x 4 years
Panel spacer
Use when only minimal space is available between drop ceilings and ceiling slabs.
Sealing material of air discharge outlet
Sealing material block air discharge openings not used in 2-way or 3-way blow.
Branch duct (direct-connection round duct)
A round duct can be attached without the need for a chamber.
A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole).
High-efficiency filter
Available in two types: 65% and 90% colorimetry.
Insulation kit for high humidity
Please use if you think the temperature and humidity inside the ceiling exceeds 30°C and RH 80%, respectively.
Fresh air intake kit
Using this kit, a duct can be
connected to take outdoor air
in.There are two chamber types that
have intake in two places: with
T-duct joint and without T-duct joint.
Note:
1. Use of options will increase operating sound.
2. Connecting ducts, fan, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
3. When a local-procured fan is used, an interlock with air conditioner is necessary.Optional PCB(KRP1C63)is required for interlocking.
4. It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending
Dạ, Sieuthimaylanh.com chào chị Thuynga!
- Giá lắp đặt cho máy lạnh Âm trần 5.0Hp là 800.000 VNĐ / bộ
- Máy có công suất làm lạnh rất cao với thời gian làm lạnh nhanh.
- Siêu tiết kiệm điện, giảm tối thiểu chi phí tiền điện cho gia định chị hàng tháng.
Nếu Anh cần tư vấn thì để lại thông tin bên em sẽ liên hệ cho mình hoặc Anh có thể gọi hotline 0909 811 373 - 090 282 0616 để được nhân viên hỗ trợ nhanh nhất nhé.
Em cảm ơn ạ.