Specifications
Made in:Brand of Japanese, Made in Thailand
Refrigerant:R410A
Type:Inverter AC - Cooling Only
Cooling Capacity:4.0 Hp - 34.100 Btu/h
Use For Room:Room area 50 - 54 m² or volume 150 - 162 m³
Power Input (Ph/V/Hz):3 Phase, 380 - 415 V, 50Hz
Power consumption (kW):2,82 KW
Refrigerant/ Liquid Pipe Diameter (mm):9.5 / 15.9
Cooling Seasonal Performance Factor (CSPF):4.73
Energy Efficiency Level:4 stars
Indoor Unit
Indoor Unit Model:FBQ100EVE
Indoor Unit Dimensions (mm):245 x 1,400 x 800 mm
Indoor Unit Net Weight (Kg):47 (kg)
Outdoor Unit
Outdoor Unit Model:RZR100MYM
Outdoor Unit Dimensions (mm):990 x 940 x 320 mm
Outdoor Unit Net Weight (Kg):73 (kg)
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Description

Design and installation flexibility 

  • With a height of only 245 mm, installation is possible even in buildings  with narrow ceiling spaces
     Indoor  unit71E100/125/140E
     Height ( mm)245
     Width (mm)1,0001,400
     Depth (mm)800
Daikin_FBQ125EVE_4
One of the industry’s most compact bodies in the mid-static pressure range.
  • Higher lift is realized by utilising built-in DC drain pump with standard accessory
Daikin_FBQ125EVE_5
  • Bottom suction is available
    Wiring and servicing can be done from the underside of the unit (an option part required).
    Daikin_FBQ125EVE_6

Daikin_FBQ125EVE_7

Comfort

  • Switchable fan speed:High/Middle/Low and Auto
    (“Auto” is applicable when BRC1E62 is used.)

Clean

  • Silver ion anti-bacterial drain pan
    A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould that cause smells and clogging.
  • Using a DC fan motor, the external static pressure can be controlled to within a range of 50 Pa to 150 P
  • Airflow rate auto adjustment function
    Controls the airflow rate using a remote controller during test run. It is automatically adjusted to approximately ±10% of the rated H tap airflow.
Daikin_FBQ125EVE_9
Comfort airflow is achieved in accordance with conditions such as duct lengthComfort airflow is achieved in accordance with conditions such as duct length
  • Interlock control
    As an energy saving feature, the room air conditioning unit can be interlocked with the hotel key card system. Using a 3rd-party building management system, air conditioning and lighting can be interlocked.
    * Field setting with remote controller
Daikin_FBQ125EVE_8
  • DIII-NET communication standard
    Easier communication and connection with the centralised control system.

Easy maintenance

  • Position of drain pan inspection opening has been modified for easier inspection work
  • Drain pan maintenance check window
    This makes it possible to inspect for drain pan dirt and to confirm drainage during installation without the use of tools.
Daikin_FBQ125EVE_1
  • Easy maintenance because the drain pan can be removed

High efficiency

  • DC fan motor and DC drain pump are utilised to improve energy efficiency

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)

When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be  installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.

Daikin_FBQ125EVE_2
Daikin_FBQ125EVE_3

Note: The under-door cutout method should be used only when there is a small volume of airflow.

Daikin_FBQ125EVE_10

Note :
1. Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2. Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3. Capacities are net, including a deduction for cooling for indoor fan motor heat.
4. External static pressure is changeable in 11 stages by remote controller.
5. The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
6. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.

Please be the first to rate Daikin Ceiling Duct AC FBQ100EVE (4.0Hp) inverter - 3 phase

0

    0 Bình luận
    CONSTRUCTION IMAGE
    z3735451114110 732c7fafae0a209ab218b666b2c4f34c
    z3696928429900 66998371e707c580258a845dd4cfb359
    z3688386324683 c03c8108d6f7812673a07192adaba832
    z3638310411342 539a2369b2fd57b9611f642f40ab0fae
    z3595620541504 f906f3f3dc0b7e34cdc41c53b5e60fe8
    z3582644212410 fc5774a8ad2c1c2bbe63e3bb04e6c3db
    z3476093713381 60fe0767a3dd16349d03e5ec6c59ef50 1
    z3299740805504 249c0044dd3ec8d65709ff9cfb125f7a 1
    z2986694571995 23efca58047b4441f338904974d61be1 1
    z2895525694725 22609f27d4af2bea1876f971a85500f9 1
    z2864163138316 32be26b42e31187397c81c2ffff8434d 1
    z3850207100948 0093ff2987a9944b323a122188aa2d4f
    z3850207096307 d004df4534a472da8d28a041ad2704d0
    z3688409899596 86b5f7a4c2a6984629c59525975637e3
    z3688409888713 072ee9e7e7b398378882bfb184c964a7
    z3476093713381 60fe0767a3dd16349d03e5ec6c59ef50
    z3399798021322 00e2cf130ad77a6d40a572a889e84abd
    z3299740805504 249c0044dd3ec8d65709ff9cfb125f7a
    z2986694571995 23efca58047b4441f338904974d61be1
    z2895525694725 22609f27d4af2bea1876f971a85500f9
    z2864163065187 2822b96a7884a51c5ccc8054749473ad
    z2600380169806 15b80da09e79b859cd17d20cf263b2c0
    0