Capacity Air Conditioner 2.0 HP | Type | Refrigerant Gas R410A |
Specifications | ||
Made in | : | Brand of Japanese, Made in Thailand |
Refrigerant | : | R410A |
Type | : | Non - Inverter AC - Cooling Only |
Cooling Capacity | : | 2.0 Hp - 17.700 Btu/h |
Use For Room | : | Room area 24 - 30 m² or volume 72 - 90 m³ ( Suitable for living room, office ) |
Power Input (Ph/V/Hz) | : | 1 Phase, 220 - 240 V, 50Hz |
Power consumption (kW) | : | 5.2 KW |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 30 mm |
Maximum Pipe Length | : | 15 m |
Maximum Elevation Length | : | 15 m |
Indoor Unit | ||
Indoor Unit Model | : | FDBNQ18MV1 |
Indoor Unit Dimensions (mm) | : | 260 x 900 x 580 mm |
Indoor Unit Net Weight (Kg) | : | 25 (kg) |
Outdoor Unit | ||
Outdoor Unit Model | : | RNQ18MV1 |
Outdoor Unit Dimensions (mm) | : | 595 x 845 x 300 mm |
Outdoor Unit Net Weight (Kg) | : | 40 (kg) |
Wide Variety of Indoor Units
Daikin meets your needs with full lineup for various types of indoor units (Ceiling mounted cassette type, Ceiling suspended type, Duct connection type and Floor standing type) and power supplies.
Navigation Remote with Simple Operation, Weekly Schedule Timer
Simple, modern designed with fresh white color matches your interior design.
Easy to use and smoother operation by following the indications
Anti-Corrosion Treatment for Outdoor Unit Heat Exchanger
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
Easy Installation and Maintenance
Pre charged for up to 15 m (Applies to RNQ30-48M)
4-direction piping offers greater layout freedom (Applies to RNQ30-48M).
Indoor unit | High | Low |
09/13/18M | 41 | 38 |
21/26M | 43 | 40 |
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
(This feature also applies to duct connection middle static pressure type.)
When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Note: The under-door cutout method should be used only when there is a small volume of airflow.
Note :
1. Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2. Capacities are net, including a deduction for cooling for indoor fan motor heat.
3. Please see fan characteristic document in detail.
4. Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Dạ xin chào anh Đạt ạ!
Cảm ơn anh đã quan tâm đến sản phẩm của sieuthimaylanh.com, kích thước ống đồng của máy này là 6/12 (mm) ạ.