Daikin Air Conditioners
Thailand
Inverter
Capacity
Air Conditioner 18.0 HP
TypeRefrigerant
Gas R410A

Daikin packaged air conditioner inverter 18.0Hp FVPR500PY1 - 3 phases - Duct connection type

Price: contact
(VAT included)
Máy lạnh tủ đứng bao gồm dàn nóng và dàn lạnh rời riêng biệt.
Specifications
Made in:Thương hiệu: Nhật - Sản xuất tại: Thái Lan
Refrigerant:R410A
Type:Inverter - loại 1 chiều (chỉ làm lạnh)
Cooling Capacity:1.0Hp - 171.000 Btu/h - 50.0 kW
Power Input (Ph/V/Hz):3 pha, 380-415V,50Hz
Power consumption (kW):23.26 kW
Refrigerant/ Liquid Pipe Diameter (mm):15.9 / 28.6
Maximum Pipe Length:70 m (Chiều dài tương đối 90 m)
Maximum Elevation Length:50 m
Indoor Unit
Indoor Unit Model:FVPR500PY1
Indoor Unit Dimensions (mm):1,870 × 1,470 × 720 mm
Indoor Unit Net Weight (Kg):250 kg
Outdoor Unit
Outdoor Unit Model:RZUR500PY1
Outdoor Unit Dimensions (mm):1,657 × 1,240 × 765 mm
Outdoor Unit Net Weight (Kg):291 kg
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Description

Dimensions (unit: mm)

Daikin indoor unit - Duct connection

Daikin outdoor unit - Duct connection

Design flexibility

Designed for long refrigerant piping

70 m maximum length and 50 m maximum level difference to cover medium- and large-scale building needs.

High external static pressure

The outdoor unit has been achieved high external static pressure up to 78.4 Pa, ensuring the efficient Display of air filter cleaning times and self-inspection function for simple maintenance. heat dissipation and stable operation of equipment in either hierarchical or intensive arrangement

Nighttime quiet operation function

The nighttime quiet operation function automatically suppresses the nighttime operating sound by reducing operation capacity to maintain the quiet environment of the neighborhood. Three selectable modes are available depending on the required level.

 

*1. Initial setting is 8 hours. Can be selected from 6, 8 and 10 hours.

*2. Initial setting is 9 hours. Can be selected from 8, 9 and 10 hours.

*3. In case of RZUR250PY1(4).

Notes

  • This function is available in setting at site.
  • The operating sound in quiet operation mode is the actual value measured by our company.
  • The relationship of outdoor temperature (load) and time shown above is just an example.

 

Reliability

Backup operation function

Centralized management system extension

Centralized management can integrate with D-BACS system with high speed data transfer. Centralized control is now available when using with Inverter packaged air conditioners. The outdoor unit has been achieved high external static pressure up to 78.4 Pa, ensuring the efficient Display of air filter cleaning times and self-inspection function for simple maintenance.

Various improvements from the factory

Air blow via connected ducts

- Comfortable air conditioning of the entire factory by connecting a blow duct at the top of the indoor unit. DUCT TYPE

Note: Ducts to be procured locally.

 

Extended operation range up to 49°C

Note: When outdoor temperature falls below 10℃, the thermostat shuts OFF, the outdoor unit stops, and operation switches from cooling to fan operation

Fan performance

Wiring Diagram of the outdoor unit

Pipeline Diagram of the outdoor unit

Space required for indoor unit installation (Unit:mm)

Space required for outdoor unit installation (unit:mm)

 

 

1. Height of the wall in the case of Models 1 and 2:

Front: 1500 mm

Suction side: 500 mm

Side view: Unlimited height

The installation space shown in this drawing is based on cooling operation at an outdoor air temperature of 35 degrees.

When the outdoor air temperature exceeds 35 degrees, or the load exceeds the maximum capacity due to the immense heat load generated by the entire outdoor unit, the suction side space is larger than the space shown in this drawing.

2. If the above wall height is exceeded, then h2/2 and h1/2 should be added to the front and side suction service areas, respectively, as shown in the figure to the right.

3. When installing, the most suitable equipment should select from the models shown above to get the best fit in the available space, always keeping in mind that enough space should be left for one person to pass through between the appliance and the wall allowing air to circulate freely.

4. Units should be installed to leave enough space in front for on-site refrigerant piping to be comfortable.

(If more devices are installed than are provided in the models above, your layout should consider the possibility of a short circuit.)

 

Specifications

 

Note :

*1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m.
*2. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.
When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.
*3. The value is the external static pressure with standard pulley

Please be the first to rate Daikin packaged air conditioner inverter 18.0Hp FVPR500PY1 - 3 phases - Duct connection type

0

    0 Bình luận
    CONSTRUCTION IMAGE
    z3735451114110 732c7fafae0a209ab218b666b2c4f34c
    z3696928429900 66998371e707c580258a845dd4cfb359
    z3688386324683 c03c8108d6f7812673a07192adaba832
    z3638310411342 539a2369b2fd57b9611f642f40ab0fae
    z3595620541504 f906f3f3dc0b7e34cdc41c53b5e60fe8
    z3582644212410 fc5774a8ad2c1c2bbe63e3bb04e6c3db
    z3476093713381 60fe0767a3dd16349d03e5ec6c59ef50 1
    z3299740805504 249c0044dd3ec8d65709ff9cfb125f7a 1
    z2986694571995 23efca58047b4441f338904974d61be1 1
    z2895525694725 22609f27d4af2bea1876f971a85500f9 1
    z2864163138316 32be26b42e31187397c81c2ffff8434d 1
    z3850207100948 0093ff2987a9944b323a122188aa2d4f
    z3850207096307 d004df4534a472da8d28a041ad2704d0
    z3688409899596 86b5f7a4c2a6984629c59525975637e3
    z3688409888713 072ee9e7e7b398378882bfb184c964a7
    z3476093713381 60fe0767a3dd16349d03e5ec6c59ef50
    z3399798021322 00e2cf130ad77a6d40a572a889e84abd
    z3299740805504 249c0044dd3ec8d65709ff9cfb125f7a
    z2986694571995 23efca58047b4441f338904974d61be1
    z2895525694725 22609f27d4af2bea1876f971a85500f9
    z2864163065187 2822b96a7884a51c5ccc8054749473ad
    z2600380169806 15b80da09e79b859cd17d20cf263b2c0
    0