Capacity Air Conditioner 4.0 HP | Type | Refrigerant Gas R32 |
Specifications | ||
Made in | : | Brand of Japanese - Made in Thailand |
Refrigerant | : | R32 |
Type | : | Inverter AC - Cooling Only |
Cooling Capacity | : | 4.0 Hp - 34.100 Btu/h |
Use For Room | : | Room Area 50 - 54 m² or Volume 150 - 162 m³ ( Suitable for living room, office ) |
Power Input (Ph/V/Hz) | : | 3 Phase, 380 - 415 V, 50Hz |
Power consumption (kW) | : | 3.01 kW |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 9.52 / 15.88 |
Maximum Pipe Length | : | 50 m |
Maximum Elevation Length | : | 30 m |
Indoor Unit | ||
Indoor Unit Model | : | FBA100BVMA |
Indoor Unit Dimensions (mm) | : | 245 x 1400 x 800 (mm) |
Indoor Unit Net Weight (Kg) | : | 47 (Kg) |
Outdoor Unit | ||
Outdoor Unit Model | : | RZF100CYM |
Outdoor Unit Dimensions (mm) | : | 695 x 930 x 350 (mm) |
Outdoor Unit Net Weight (Kg) | : | 48 (Kg) |
Daikin's new Inverter technology models reduce energy consumption during the cooling process.
With a height of only 245 mm, installation is possible even in buildings with narrow ceilings.
The discharge pipe height is increased by 850 mm thanks to the use of the pre-installed DC drain pump with standard accessories.
The antibacterial method is integrated in the indoor unit, using silver ions in the drain to prevent the growth of slime, bacteria, mold causing odors and blockages (the life of the silver ion tube depends on into the use environment, but should be replaced every 2 to 3 years).
Daikin's DC inverter product line is equipped with a reluctance DC helical compressor.
Reluctance DC helical compressors use 2 different types of torque: Neodym magnet*1 and reluctance torque*2.
This motor saves energy because during operation it requires less power but still produces more power than traditional AC and DC motors.
Daikin's exclusive refrigerant cooling system delivers high cooling performance even at high outdoor temperatures.
Larger heat exchanger area increases machine efficiency.
The use of a V-shaped propeller blade simulates the performance of a swan's wing, which ensures even and lossless air flow.
Using a DC fan motor the external static pressure can be adjusted between 50 Pa and 150 Pa.
Pleasant airflow is achieved depending on conditions such as duct length.
When the air conditioners in two rooms are turned on at the same time, the amount of air supplied to each room must be recirculated back to the air conditioner. To ensure this, a ventilation system must be installed for each room or a ventilation door must be installed in a compartment on the wall or under the door between two rooms.
Control the air flow by remote control during the test run.
Air volume is adjusted automatically to approximately +/- 10% high wind speed.
As an energy-saving feature, the air conditioner can be interlocked with the hotel's magnetic door system. With the use of a third building management system, lighting and air conditioning can be controlled with an interlock mechanism.
Easy communication and connection to the central control system.
Suction line available at the bottom of the device
Adjusted for easier inspection.
This window makes it possible to check for dirt clinging to the drain pan and identify drainage during installation without the use of tools.
Note:
1 Rated cooling capacity is based on the following conditions: Room temperature 27°CDB, 19° CWB; outdoor temperature 35° CDB, 24° CWB; refrigerant conduit equivalent to 7.5 m (horizontally)
2 Power is the actual value, deducting heat from the indoor unit motor.
3 External static pressure can be changed in 11 degrees by remote control.
4 Conversion value in anechoic room conditions. If measured under actual installation conditions, the actual value is often higher than the specification due to environmental noise and echo.
5 The air filter is not a standard accessory, but it is recommended to attach it to the ductwork on the intake side. Select dust filtration efficiency (gravity method) 50% or more.