Capacity Air Conditioner 2.0 HP | Type | Refrigerant Gas R410A |
Specifications | ||
Made in | : | Brand of Japanese, Made in Thailand |
Type | : | Inverter AC - Cooling Only |
Cooling Capacity | : | 2.0 Hp |
Use For Room | : | Room area 24 - 27 m² or volume 72 - 81 m³ ( Suitable for bedroom) |
Power Input (Ph/V/Hz) | : | 1 phase, 220 - 240V, 50Hz |
Power consumption (kW) | : | 5,0 Kw |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 6.4 / 12.7 |
Dimensions (H x W x D) | : | 290 x 1.050 x 238 (mm) |
Weigh | : | 12 kg |
SUPER MULTI NX
The Daikin SUPER MULTI NX lets you build a highly efficient multi room air conditioning system by connecting up to five indoor units to a single outdoor unit.
Air condition your entire home with a single outdoor unit
Features
Space Saving
High energy saving and quiet operation
With the combination of:
We have created:
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory
2MKS40: 43 dB (A)
2MXS50: 45 dB (A)
Long piping length for installation flexibility
The ample maximum piping length of 80 m permits more freedom in the placement of air conditioner units and facilitates the optimisation of interior space
Wide Variety of Indoor Unit
Stylish indoor units for elegant interiors
Smart control
Connectable at up to 200% of the outdoor unit capacity class
If all indoor units will not be operated simultaneously, for example, during daytime use of the living room unit or nighttime use of the three bedroom units, the sum of the capacity classes of all indoor units that can be connected is up to 200% of the outdoor unit capacity class
Notes:
1. When an indoor unit is turned on, if the sum of the capacity classes of all indoor units exceeds the limit for simultaneous operation, the unit waits on standby.
2. Even an indoor unit that was initially set as prioritised under Priority-Room Setting waits on standby under the above condition 1.
3. When an indoor unit is turned off, the sum of the capacity classes of all indoor units is within the limit for simultaneous operation, the unit waiting on standby starts automatically.
* Indoor units can be connected at up to 200% of outdoor units capacity class. All indoor units cannot be operated simultaneously
Indoor Unit
Clean air
Quiet operation
Wall-mounted type indoor units achieve quiet sound levels of 22 dB (A) during Indoor Unit Quiet Operation.
Easy cleaning
Flat panel can be cleaned with just a single pass of a cloth across its smooth surface
3-D Airflow
3-D airflow combines vertical and horizontal auto-swing to circulate air to every part of a room for uniform cooling of even large spaces.
Wall-mounted type