Capacity Air Conditioner 10.0 HP | Type | Refrigerant Gas R410A |
Specifications | ||
Made in | : | Thương hiệu : Nhật - Sản xuất tại : Thái Lan |
Refrigerant | : | R-410A |
Type | : | Inverter (Tiết kiệm điện) - loại 2 chiều lạnh/sưởi. |
Cooling Capacity | : | 10.0 Hp (10.0 Ngựa) - 81,300 Btu/h - 24.0 kW |
Heating Capacity | : | 27.0 ( 5.5 ~ 31.5 ) kW |
Use For Room | : | Diện tích 130 -134 m2 hoặc 390 -402 m3 khí |
Power Input (Ph/V/Hz) | : | 3 Pha 380-415V, 50Hz |
Power consumption (kW) | : | 7.98 / 7.20 kW |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 12.7 / 25.4 |
Maximum Pipe Length | : | 70 m |
Maximum Elevation Length | : | 30 m |
Indoor Unit | ||
Indoor Unit Model | : | FDU250VG |
Indoor Unit Dimensions (mm) | : | 379 x 1,600 x 893 mm |
Indoor Unit Net Weight (Kg) | : | 89 kg |
Outdoor Unit | ||
Outdoor Unit Model | : | FDC250VSA |
Outdoor Unit Dimensions (mm) | : | 1,505 x 970 x 370 mm |
Outdoor Unit Net Weight (Kg) | : | 143 kg |
The user can set the external static pressure (E.S.P.) by adjusting the E.S.P. button on the wired controller. The indoor unit will control the fan speed to ensure the airflow at each different rate. In addition, the user can adjust the desired static pressure by calculating the airflow and pressure loss on the duct, then set it on the remote cord.
The new advanced technology of M.H.I. extends the spectrum of heating and cooling systems.
It helps the device work in outdoor temperatures as low as -15 °C / -20 °C during heating and-15 °C during cooling operations.
Fan blades and motor can be removed from the right side of the indoor unit. So maintenance can be done quickly from the right or bottom side of the machine.
The indoor unit is completely hidden on the ceiling, which is very suitable for decorative interior spaces.
Efficiency is improved when using a high-efficiency D.C. fan motor and heat exchanger.
When the drain trough is dirty, the user can check it quickly through this transparent window without removing the gutter.
When selecting the Powerful-Hi mode
Noise level: 100VN(S)AVF2 44dB(A), 125VN(S)AVF 45dB(A), 140VN(S)AVF 47dB(A), 200/250VSAVG:52dB(A),71VNPVF1 38dB(A), 90VNPVF2 44dB (A), 100VNP1VF2 44dB(A)
Airflow: 100VN(S)AVF2 36m3/min, 125VN(S)AVF 39m3/min, 140VN(S)AVF 48m3/min, 200/250VSAVG 80m3/min, 71VNPVF1 24m3/min, 90VNPVF2 36m3/min, 100VNP1VF2 36m3 /min
Note:
Conditional Measured Parameters (IOS-T1)
Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. of 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temperature 7˚CDB, 6˚CWB.
* Indicators obtained in the laboratory. During operation, these stats will change higher due to ambient conditions
** Static pressure can be changed by setting on the controller. The maximum static pressure is set to “High static pressure.” The noise level value will be higher than 5dB(A) when the static pressure level is outside 200Pa
*** If a cooling operation occurs when the outdoor temperature is -5oC or below, the outdoor unit must be installed in a place that is not affected by natural wind. If the wind blows, the low pressure will drop, and the compressor frequency will increase, which reduces capacity and can cause damage to the machine.