Capacity Air Conditioner 1.0 HP | Type | Refrigerant Gas R410A |
Specifications | ||
Made in | : | Japanese brand, Made in Thailand |
Refrigerant | : | R410A |
Type | : | Non - Inverter AC - Cooling Only |
Cooling Capacity | : | 1.0 Hp - 8.530 Btu/h |
Use For Room | : | Room Area 12 - 15 m² or Volume 36 - 45 m³ ( Suitable for Bedroom) |
Power Input (Ph/V/Hz) | : | 1 phase, 220 - 240V, 50Hz |
Power consumption (kW) | : | 0,77 Kw |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 6.35 / 9.52 |
Energy Efficiency Ratio (EER) | : | 4.804 |
Energy Efficiency Level | : | 5 star |
Indoor Unit | ||
Indoor Unit Model | : | SRK10YN-S5 |
Indoor Unit Dimensions (mm) | : | 262 x 769 x 210 (mm) |
Indoor Unit Net Weight (Kg) | : | 7 (kg) |
Outdoor Unit | ||
Outdoor Unit Model | : | SRC10YN-S5 |
Outdoor Unit Dimensions (mm) | : | 540 x 640 x 275 (mm) |
Outdoor Unit Net Weight (Kg) | : | 25 (kg) |
WALL MOUNTED DULUXE INVERTER YN : SRK10YN-S5
50% Saving power compared with standard modle 1*
Saving energy index CSPF : 4.804 - Achieving energy level 5*
Clean Operation/Filter
Natural solar Filter
It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing to the sunlight.
Comfortable Functions
Fuzzy auto mode
Automatically, the unit determines its operating mode and adjusts the inverter frequency..
Automatic Operation
The air conditioner automatically selects from among heating, cooling and dry operations.
" HI POWER" operation
The unit can operation continuously in " HI POWER" mode for 15 minutes. This mode is convenient to reach the desired temperature quickly.
COMFORTABLE AIR FLOW FUNCTIONS
Auto flap mode
Whatever the operating mode is the unit automatically selects the optimal angle.
Memory flap
While the flap is swinging it can be stopped at any angle desired. The flap returns to the position that it was in when operation last stopped.
Up/Down flap swing
The UP/DOWN flap can be adjust to the preferred operations angle, ranging from horizontal to perpendicular.
Maintenance & Prevention Funtions
Self-Diagnostic Funtion
In the case that the air conditioner malfunctions an internal microcomuter automatically runs a self-diagnosis.
One Action Filter
For easy maintenace filter can be taken off and put on easylu by just 1 slide action
CONVENIENCE & ECONOMY FUNCTIONS
Economy Mode
The unit realizes effective energy saving operation, while still keepiing a comfortable cooling and heating.
Dry operation
The unit dehumidifies the room by intermittent cooling operation.
Off timer
the unit stops autpmatically at the set time.
On timer
This facility enables the operation to start a little earlier, so thât the room approaches optimum temperature at ON time when te operation is started by ON _TMER.
Sleep Mode
The room temperature is automatically controlled during the set sleep mode period, ensuring that room temperature will not get too cold or too hot
24-hour On/Off Programmable Timer
By combining a start timer with a stop timer, you can register two timer operations a day. Once set, timers will faithfully start or stop the system at a specified time of the day repeatedly.
OTHERS
Back-up Switch
On the main unit, there is a backup on/off switch, which is useful when you can't use remote control or batteries are
Auto Restart Funtion
Power blackout auto restart function is a function that records, the operational status of the air-conditioner immediately prior to it being switched off by a power cut and the automatically resumes operations at that point after the power has been restored.
Item/Model | Indoor unit | SRK10YN-S5 | |
Outdoor unit | SRC10YN-S5 | ||
Power source | 1 Pha, 220/230V, 50Hz | ||
Capacity | kW | 2.5( 1.0 ~ 2.8) | |
BTU/h | 8,530 ( 3,412~ 9,554) | ||
Input | kW | 0.77(0.25~ 1.01) | |
EER | W/W | 4.804 | |
Current | A | 3.7 | |
Exterior dimensions (H x W x D) | Indoor | mm | 262 x 769 x 210 |
Outdoor | mm | 540 x 645(+57) x 275 | |
Netweight | Indoor | kg | 7.0 |
Outdoor | kg | 25 | |
Refrigerant | R410A | ||
Refrigerant piping | Liquid line | mm | ø 6.35 |
Gas line | mm | ø 9.52 | |
Connecting wiring | 1.5 mm² x 4 Scores ( including earth cable) | ||
Connecting method | Terminal block ( Screw fixing type) |