1. High Efficiency & Comfort
Vector control
New applied Vector control has a high efficiency and many new advanced features.
- Smooth operation from low speed to high speed.
- Smooth Sine Voltage Wave form are attained.
- Energy efficiency is further improved in low speed range.
Long-chorded 3 propeller fan with serration
Fan blade design adapted from Mitsubishi Heavy Industries aerospace division - with serrated edges that deliver increased air volume with less power input.
DC Fan Motor
Employment of DC fan motor has enabled to realize an excellent efficiency of approximate 60% higher than previous models.
Oil level control capability
Our proprietary technology of adjusting oil level for combination of two or three outdoor units has realized leveled operation rate, keeping performance of the units and ensuring long life of the system.
4~6HP (Micro)
Compact High Efficient Heat Exchanger
- Optimizing relationship of the air flow velocity & fin pattern.
- Improvement of air distribution Maximizing efficiency of heat exchanger.
2. Design Flexibility
Indoor unit capacity connection
150% capacity connection.
Connectable indoor units
Connect up to 8 indoor units.
Easy Transportation & Installation
Due to realization of significant reduction in size and foot print which is one of the smallest in the industry, transportation in an elevator made for six persons (Width:1400mm, Depth:850, Open area:800mm) is possible, eliminating cost of a crane and reducing labor.
Blue Fin
Due to application of blue coated fins for the heat exchanger of new outdoor unit, corrosion resistance has been improved compared to current models.
Advantages of Mitsubishi Heavy VRV Heat pump systems Micro inverter(5.0Hp) FDC140KXES6 - 3 Phase
- Connect up to 8 indoor units/up to 150% capacity
- High efficiency with COP (in cooling) up to 4.0.
- KX6 employs DC inverter compressors ONLY.
- Industry leading total piping length up to 100m and a maximum pipe run of 70m.
Specifications
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. ‘tonne(s) of CO2 equivalent’ means a quantity of greenhouse gases- expressed as the product of the weight of the greenhouse gases in metric tonnes and of their global warming potential.