Capacity Air Conditioner 5.0 HP | Type | Refrigerant Gas R410A |
Specifications | ||
Made in | : | Brand of Japanese, Made in Thailand |
Refrigerant | : | R410A |
Type | : | Non - Inverter AC - Cooling Only |
Cooling Capacity | : | 5.0 Hp - 46.620 Btu/h |
Use For Room | : | Room Area 64 - 67 m² or Volume 192 - 201 m³ |
Power Input (Ph/V/Hz) | : | 3 Phase, 380-415V, 50Hz |
Power consumption (kW) | : | 4,46 Kw |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 9.52 / 15.88 |
Maximum Pipe Length | : | 50 (m) |
Maximum Elevation Length | : | 15 (m) |
Energy Efficiency Ratio (EER) | : | 2.80 (COP) |
Indoor Unit | ||
Indoor Unit Model | : | FDT125CR-S5 |
Indoor Unit Dimensions (mm) | : | 298 x 840 x 840 (mm) |
Indoor Unit Net Weight (Kg) | : | 27 (kg) |
Panel | ||
Panel Dimensions (mm) | : | 35 x 950 x 950 (mm) |
Panel Net Weight (Kg) | : | 5.5 (kg) |
Outdoor Unit | ||
Outdoor Unit Model | : | FDC125CR-S5 |
Outdoor Unit Dimensions (mm) | : | 845 x 970 x 370 (mm) |
Outdoor Unit Net Weight (Kg) | : | 87 (kg) |
CEILING CASSETTE NON INVERTER FDT - 4 WAY
Arrangement of installation
Checking from access ports with detachable covers at each corner, arrangement of installation balancer of indoor unit can be available without removing a panel.
Warkability is improved and time of installation is reduced.
Easy checking of drain pan
Easy checking of drain pan condition is available by removing corrner lid only.
Due to new design changing fan motor is available without removing a panel.
700MM DRAINPUMP
Drain can be disscharged upwardsby 700mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location and 260mm flexible hose as a standard equipment supports easy workability.
REMOTE CONTROL
COMFORTABLE FUNTIONS
Fuzzy auto mode
Automatically, the unit determines its operating mode and adjusts the inverter frequency..
Automatic Operation
The air conditioner automatically selects from among heating, cooling and dry operations.
COMFORTABLE AIR FLOW FUNCTIONS
Auto flap mode
Whatever the operating mode is the unit automatically selects the optimal angle.
Memory flap
While the flap is swinging it can be stopped at any angle desired. The flap returns to the position that it was in when operation last stopped.
Up/Down flap swing
The UP/DOWN flap can be adjust to the preferred operations angle, ranging from horizontal to perpendicular.
Maintenance & Prevention Funtions
Microcomputer- Operated Defrosting
This mode automatically eliminates frost and helps minimize excessive operation in other modes.
Self-Diagnostic Funtion
In the case that the air conditioner malfunctions an internal microcomuter automatically runs a self-diagnosis.
CONVENIENCE & ECONOMY FUNCTIONS
Dry operation
The unit dehumidifies the room by intermittent cooling operation.
Sleep Mode
The room temperature is automatically controlled during the set sleep mode period, ensuring that room temperature will not get too cold or too hot
Off Timer
The unit stops automatically at the set time.
On Timer
This facility enables the operation to start a littel earlier, so that the room approaches optimum temperaure at ON time when the operation is started by ON-TIMER.
Thus it will try to e at the temperature you want.
24-hour On/Off programmanle timer
by combining a start timer with a stop timer, you can register two timer operationsa day. Once set, timers will faithfully start or stop the system at a specified time of the day repeatedly.
OTHERS
Back-up Switch
On the main unit, there is a backup on/off switch, which is useful when you can't use remote control or batteries are
Auto Restart Funtion
Power blackout auto restart function is a function that records, the operational status of the air-conditioner immediately prior to it being switched off by a power cut and the automatically resumes operations at that point after the power has been restored.