5
25
Mitsubishi Heavy Industries Air Conditioners
Thailand
Inverter
Capacity
Air Conditioner 4.0 HP
TypeRefrigerant
Gas R410A

Mitsubishi Heavy duct connected air conditioner inverter FDUM100VF2 - FDC100VNP (4.0Hp)

Listed price54,590,000
Price45,800,000
(VAT included)
Saving: 8,790,000
Specifications
Made in:Brand of: Japan - Manufactures: Thailand
Refrigerant:R-410A
Type:Inverter (save energy) - two-way (cooling/heating).
Cooling Capacity:4.0 Hp - 34,100 Btu/h - 10.0 kW
Heating Capacity:11.2 ( 2.5 ~ 12.5 ) kW
Use For Room:Area 50 - 54 m² or 150 - 162 m³
Power Input (Ph/V/Hz):1 Phase 220 - 240 V, 50Hz
Power consumption (kW):3.00 / 2.93 kW
Refrigerant/ Liquid Pipe Diameter (mm):9.52 / 15.88
Maximum Pipe Length:30 m
Maximum Elevation Length:20 m
Indoor Unit
Indoor Unit Model:FDUM100VF2
Indoor Unit Dimensions (mm):280 x 1,370 x 740 mm
Indoor Unit Net Weight (Kg):54 kg
Outdoor Unit
Outdoor Unit Model:FDC100VNP
Outdoor Unit Dimensions (mm):845 x 970 x 370 mm
Outdoor Unit Net Weight (Kg):70 kg
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Description

Thin design

Mitsubishi Heavy duct connected air conditioner inverter FDUM100VF2 - FDC100VNP (4.0Hp) with compact design only 280mm can easily install in any different space. Especially areas with low ceilings.

thiet-ke-mong

Automatic external static pressure (E.S.P)

You can set external static pressure (E.S.P) by method of manual setting on remote control.

 

The outdoor unit is compact in design

Usage of lead-free welding products, compliance with RoHS requirements, environmental protection 

To prevent exposure to the global environment, all kinds of our products have used lead-free solder alloy content in manufacturing. Include six types of toxic chemicals that we do not use, including Pb, Hg, Cd, Cr6+, PBB, PBDE added to the RoHS standard in the European (EU) markets as of July 1 / 2006.

In Vietnam, according to Circular No. 30/2011/TT-BCT of 10/08/2011, which governs the allowable levels of hazardous chemicals in electrical, electronic products and the appendix to 6 forms of chemicals above.

Mitsubishi Heavy Industries implemented by the RoHS standard do not use six toxic chemicals equal to IEC 62321 according to Decision No. 4693/QD-BCT (Circular No. 30/2011/TT-BCT) for All Mitsubishi Heavy Industries brand air conditioners on the Vietnam market.

su-dung-vat-lieu-han-khong-chi

Seer & SCOP higher

Although the nominal efficiency is lower than that of the Hyper Inverter type, SEER & SCOP is higher by optimum control.

hieu-suat-danh-dinh-fdum100vf2

Easy to transport and install

New control of inverter (Vector control) 

The new inverter control technology is based on vector control technology, providing the highest operating efficiency: 

-Quiet operation from low to high speed. 

-Achieve smooth variations in sinusoidal voltage. 

- Energy efficiency is significantly in the low-speed range.

Improved maintenance space

The propeller and the fan engine can separate from the right side of the indoor machine. Maintenance can conduct from the right side or the bottom of the unit.

Improved installation capacity

Drain pump installed with pipe lift of 600mm. The indoor unit has hidden under the ceiling, suitable for luxurious interior space.

lap-dat-thuan-tien

Window inspections window

When the drain pan is dirty, you can easily check it through this transparent window without having to remove the drain.

Filters and control system (optional)

Technical specification

thong-so-ky-thuat-fdum71vf1

When you choose the powerful-Hi mode
 Noise level:125VSAPVF 36dB(A), 140VSAPVF1 38dB(A), 200VSAPVF2 44dB(A), 250VSAPVF 45dB(A), 140VSTVF 37dB(A), 200VSATVF1 38dB(A), 71VNPVF1 38dB(A), 90VNPVF2 44dB(A), 100VNP1VF2 44dB(A)
Air flow: 125VSAPVF 20m3/min, 140VSAPVF1 24m3/min, 200VSAPVF2 36m3/min, 250VSAPVF 39m3 /min, 140VSTVF 13m3/min, 200VSATVF1 24m3/min, 71VNPVF1 24m3/min, 90VN PVF2 36m3/min, 100VNP1VF2 36m3/min
Note:
 Parameters are measure under conditions (IOS-T1)
 Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. By 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.

* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions
** Indicators only apply when operating one indoor unit
*** Static pressure can change by setting on the controller. The maximum static pressure on "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa**** If cooling operation carries out when the outdoor temperature is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the low pressure will slip off, and the compressor frequency will increase, which reduces the capacity and can lead to damage.

Please be the first to rate Mitsubishi Heavy duct connected air conditioner inverter FDUM100VF2 - FDC100VNP (4.0Hp)

0

    0 Bình luận
    CONSTRUCTION IMAGE
    z3835073471331 49d745e00984b9cc06cc8c16cc1b5da7
    z3676051930823 a83e776fd6fdcc49b186d7d706f304f8
    z3651919970872 aa0d96da9ff92fb7370892f4cbf667af
    z3535719300901 c4dcd8f2e47eb72fdd2850085f25b378
    z3442867671058 18ed939b0949681f1cb2c46de934dcad
    z3441676857682 a298db86ad1547a60b75c5075e37b24d
    z3437509096020 170343d6b20ca208eaa2568f636f9368
    z3413971513042 6fd6a277c83f987082d93455f86aa0f1
    z3413955255202 b82f52f68a9e31e4ddffe86a232a31ff
    z2944299579372 095a6a804266ffa1982cc993b5d92b1d
    z2600379841126 487ecb86fa9eb46e39fdb59ac5c19110
    z2516102285384 92d3d8073b7051f22bda0ece3709da51
    z2516102231479 c01d2f019d800eeab3d691ab898b7d26
    z2023338457729 0f98fb2be46403798dc3f28d0d435117
    z2023338153794 121821abb327b3fc5a54fa54669b163f
    0