Mitsubishi Heavy Industries Air Conditioners
Thailand
Inverter
Capacity
Air Conditioner 6.0 HP
TypeRefrigerant
Gas R410A

Mitsubishi Heavy duct connected air conditioner inverter FDUM140VF - FDC140VNA (6.0Hp)

Listed price70,530,000
Price59,050,000
(VAT included)
Saving: 11,480,000
Specifications
Made in:Brand of: Japan - Manufactures: Thailand
Refrigerant:R-410A
Type:Inverter (save energy) - two-way (cooling/heating).
Cooling Capacity:6.0 Hp - 47,800 Btu/h - 14.0 kW
Heating Capacity:15.5 ( 4.0 ~ 16.5 ) kW
Use For Room:Area 77 - 80 m² or 231 - 240 m³
Power Input (Ph/V/Hz):1 Phase 220 - 240 V, 50Hz
Power consumption (kW):4.93 / 4.21 kW
Refrigerant/ Liquid Pipe Diameter (mm):9.52 / 15.88
Maximum Pipe Length:50 m
Maximum Elevation Length:50/15 m
Indoor Unit
Indoor Unit Model:FDUM140VF
Indoor Unit Dimensions (mm):280 x 1,370 x 740 mm
Indoor Unit Net Weight (Kg):54 kg
Outdoor Unit
Outdoor Unit Model:FDC140VNA
Outdoor Unit Dimensions (mm):845 x 970 x 370 mm
Outdoor Unit Net Weight (Kg):80 kg
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Description

may-lanh-giau-tran-noi-ong-gio-mitsubishi-heavy-fdum140vf-6-0-hp

Thin design

Mitsubishi Heavy duct connected air conditioner inverter FDUM140VF - FDC140VNA (6.0Hp)  with compact design only 280mm can easily install in any different space. Especially areas with low ceilings.

thiet-ke-mong

Automatic external static pressure (E.S.P)

You can set external static pressure (E.S.P) by method of manual setting on remote control.

 

Range of Operation

The new advanced technology of MHI extends the spectrum of heating and cooling systems. 

It helps the device work in outdoor temperatures as low as-15 °C/-20 °C during heating and-15 °C during cooling operations.

Micro-Inverter technology for the optimal saving of electricity

micro-inverter-fdum125vf

Reduced size and increased efficiency due to the use of a DC 1-way dual rotor compressor (types 4 - 6 Hp) 

Use a DC dual-rotor compressor for maximum high-speed operation up to 120 rpm to provide the necessary power. 

Optimization of compressor operation via vector control and start current is significantly improved compared to previous models. Besides, vibration is a reduction.

may-nen-fdum125vf

A vector control method is a technical way of maximizing control by transforming current waves into a sinusoidal waveform.

he-dieu-khien-vector-fdum125vf

Pipe length

 

* When the outdoor unit install is 30m or higher than the indoor unit, please set SW5-2 upon this PCB controller to "On".

Quiet operation

Improved maintenance space

The propeller and the fan engine can separate from the right side of the indoor machine. Maintenance can conduct from the right side or the bottom of the unit.

Improved installation capacity

Drain pump installed with pipe lift of 600mm. The indoor unit has hidden under the ceiling, suitable for luxurious interior space.

lap-dat-thuan-tien

Window inspections window

When the drain pan is dirty, you can easily check it through this transparent window without having to remove the drain.

Filters and control system (optional)

Technical specification

thong-so-ky-thuat-fdum125vf

When you choose the powerful-Hi mode

Noise level: 100VN (S) AVF2 44dB (A), 125VN (S) AVF 45dB (A), 140VN (S) AVF 47dB (A), 100VN (S) APVF 37dB (A), 125VNAPVF 36dB (A), 140VNAPVF1 38dB (A), 140VNATVF 37dB (A)

Air flow: 100VN (S) VF2 36m3 / min, 125VN (S) VF 39m3 / min, 140VN (S) VF 48m3 / min, 100VN (S) PVF 13m3 / min, 125VNPVF 20m3 / min, 140VNPVF1 24m3 / min, 140VNTVF 13m3 / min

Note:

Parameters are measure under conditions (IOS-T1)

Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. By 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.

* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions

** Indicators only apply when operating one indoor unit

*** Static pressure can change by setting on the controller. The maximum static pressure on "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa

**** If cooling operation carries out when the outdoor temperature is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the low pressure will slip off, and the compressor frequency will increase, which reduces the capacity and can lead to damage.

Please be the first to rate Mitsubishi Heavy duct connected air conditioner inverter FDUM140VF - FDC140VNA (6.0Hp)

0

    0 Bình luận
    CONSTRUCTION IMAGE
    z3835073471331 49d745e00984b9cc06cc8c16cc1b5da7
    z3676051930823 a83e776fd6fdcc49b186d7d706f304f8
    z3651919970872 aa0d96da9ff92fb7370892f4cbf667af
    z3535719300901 c4dcd8f2e47eb72fdd2850085f25b378
    z3442867671058 18ed939b0949681f1cb2c46de934dcad
    z3441676857682 a298db86ad1547a60b75c5075e37b24d
    z3437509096020 170343d6b20ca208eaa2568f636f9368
    z3413971513042 6fd6a277c83f987082d93455f86aa0f1
    z3413955255202 b82f52f68a9e31e4ddffe86a232a31ff
    z2944299579372 095a6a804266ffa1982cc993b5d92b1d
    z2600379841126 487ecb86fa9eb46e39fdb59ac5c19110
    z2516102285384 92d3d8073b7051f22bda0ece3709da51
    z2516102231479 c01d2f019d800eeab3d691ab898b7d26
    z2023338457729 0f98fb2be46403798dc3f28d0d435117
    z2023338153794 121821abb327b3fc5a54fa54669b163f
    1