5
25
Mitsubishi Heavy Industries Air Conditioners
Thailand
Inverter
Capacity
Air Conditioner 1.5 HP
TypeRefrigerant
Gas R410A
  • Slim design.
  • Automatic static pressure control (E.S.P).
  • Hyper Inverter technology saves energy effectively.
  • Easy installation.

Mitsubishi Heavy duct connected air conditioner inverter FDUM40VF (1.5Hp)

Listed price33,470,000
Price28,200,000
(VAT included)
Saving: 5,270,000
Specifications
Made in:Brand of: Japan - Manufactures: Thailand
Refrigerant:R-410A
Type:Inverter (save energy) - two-way (cooling/heating).
Cooling Capacity:1.5 HP - 13,600 Btu/h - 4.0 KW
Heating Capacity:4.5 kW
Use For Room:Area 16 - 20 m² or 48 - 60 m³ (suitable for living room, office)
Power Input (Ph/V/Hz):1 Phase 220 - 240 V 50Hz
Power consumption (kW):0.952 kW
Refrigerant/ Liquid Pipe Diameter (mm):6.35 / 12.7
Maximum Pipe Length:30 m
Maximum Elevation Length:20 m
Indoor Unit
Indoor Unit Model:FDUM40VF
Indoor Unit Dimensions (mm):280 x 750 x 635 mm
Indoor Unit Net Weight (Kg):29 kg
Outdoor Unit
Outdoor Unit Model:SRC40ZSX-S
Outdoor Unit Dimensions (mm):640 x 800 x 290 mm
Outdoor Unit Net Weight (Kg):45 kg
Area and air volume calculated by room in ideal conditions, closed room, concrete wall, good insulation, no direct ventilation wc, washbasin...
Description

Thin design

Mitsubishi Heavy duct connected air conditioner inverter FDUM40VF (1.5Hp) with compact design only 280mm can easily install in any different space. 

thiet-ke-mong

Automatic external static pressure (E.S.P)

You can set external static pressure (E.S.P) by method of manual setting on remote control.

 

 

Powerful heating mode

The new advanced technology of MHI extends the spectrum of heating and cooling systems. It helps the device operate the heating system down to-20°C.

Hyper Inverter technology saves energy effectively

The outdoor unit integrated with modern advanced technology with high efficiency, efficient heating operation, and the ability to connect long pipes. Contribute to environmental conservation by saving electricity, allowing installation of the devices (4 ~ 6HP) can be heated to-20oC under ambient temperature conditions. The flexible design has improved for pipe lengths of up to 100m.hyper-inverter

Copper tube length - 100m (hyper inverter 4-6hp)

Length of the preloaded gas pipeline up to 30m

The volume of pre-charged cold gas for the pipeline is up to 30m in length. It helps to minimize the need to add refrigerant on site, avoid overcharging or lack of gas, make installation easy and quick.

 

* Applying Hyper Inverter models 1.5 ~ 2.5HP, Standard Inverter is 15m.

 

 

Monitoring of functions

Equipped with RS232C for the direct link to a personal computer, our service program is easy to control and run ('Mente PC').chuc-nang-giam-sat

Improved maintenance space

The propeller and the fan engine can separate from the right side of the indoor machine. Maintenance can conduct from the right side or the bottom of the unit.

Improved installation capacity

Drain pump installed with pipe lift of 600mm. The indoor unit has hidden under the ceiling, suitable for luxurious interior space.

lap-dat-thuan-tien

Window inspections window

When the drain pan is dirty, you can easily check it through this transparent window without having to remove the drain.

Technical specification

Thông số kỹ thuật 

thong-so-ky-thuat-fdum40vf

 

When you choose the powerful-Hi mode

Noise level: 40/50ZSXVF 37dB(A), 60ZSXVF 36dB(A), 71VNXVF1 38dB(A), 100VN(S)XVF2 44dB(A), 125VN(S)XVF 45dB(A), 140VN(S)XVF 47dB(A)
Air flow: 40/50ZSXVF 13m3/min, 60ZSXVF 20mm3/min, 71VNXVF1 24m3/min, 100VN(S)XVF2 36m3/min, 125VN(S)XVF 39m3/min, 140VN(S)XVF 48m3/min.
Note:
 Parameters are measure under conditions (IOS-T1)
 Cooling: Room temperature 27˚CDB, 19˚CWB,  and outdoor temperature. By 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.

* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions

** Static pressure can change by setting on the controller. The maximum static pressure on "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa

**** If cooling operation carries out when the outdoor temperature is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the low pressure will slip off, and the compressor frequency will increase, which reduces the capacity and can lead to damage.

Please be the first to rate Mitsubishi Heavy duct connected air conditioner inverter FDUM40VF (1.5Hp)

0

    0 Bình luận
    CONSTRUCTION IMAGE
    z3835073471331 49d745e00984b9cc06cc8c16cc1b5da7
    z3676051930823 a83e776fd6fdcc49b186d7d706f304f8
    z3651919970872 aa0d96da9ff92fb7370892f4cbf667af
    z3535719300901 c4dcd8f2e47eb72fdd2850085f25b378
    z3442867671058 18ed939b0949681f1cb2c46de934dcad
    z3441676857682 a298db86ad1547a60b75c5075e37b24d
    z3437509096020 170343d6b20ca208eaa2568f636f9368
    z3413971513042 6fd6a277c83f987082d93455f86aa0f1
    z3413955255202 b82f52f68a9e31e4ddffe86a232a31ff
    z2944299579372 095a6a804266ffa1982cc993b5d92b1d
    z2600379841126 487ecb86fa9eb46e39fdb59ac5c19110
    z2516102285384 92d3d8073b7051f22bda0ece3709da51
    z2516102231479 c01d2f019d800eeab3d691ab898b7d26
    z2023338457729 0f98fb2be46403798dc3f28d0d435117
    z2023338153794 121821abb327b3fc5a54fa54669b163f