Capacity Air Conditioner 5.0 HP | Type | Refrigerant Gas R410A |
Specifications | ||
Made in | : | Brand of: Japan - Manufactures: Thailand |
Refrigerant | : | R-410A |
Type | : | Inverter (save energy) - two-way (cooling/heating). |
Cooling Capacity | : | 5.0 Hp - 42,700 Btu/h - 12.5 kW |
Heating Capacity | : | 14.0 ( 4.0 ~ 16.0 ) kW |
Use For Room | : | Area 64 - 67 m² or 192 - 201 m³ |
Power Input (Ph/V/Hz) | : | 1 Phase 220 - 240 V, 50Hz |
Power consumption (kW) | : | 4.36 / 3.69 kW |
Refrigerant/ Liquid Pipe Diameter (mm) | : | 9.52 / 15.88 |
Maximum Pipe Length | : | 50 m |
Maximum Elevation Length | : | 50/15 m |
Indoor Unit | ||
Indoor Unit Model | : | FDUM125VF |
Indoor Unit Dimensions (mm) | : | 280 x 1,370 x 740 mm |
Indoor Unit Net Weight (Kg) | : | 54 kg |
Outdoor Unit | ||
Outdoor Unit Model | : | FDC125VNA |
Outdoor Unit Dimensions (mm) | : | 845 x 970 x 370 mm |
Outdoor Unit Net Weight (Kg) | : | 80 kg |
Mitsubishi Heavy duct connected air conditioner inverter FDUM125VF - FDC125VNA (5.0Hp) with compact design only 280mm can easily install in any different space. Especially areas with low ceilings.
You can set external static pressure (E.S.P) by method of manual setting on remote control.
The new advanced technology of MHI extends the spectrum of heating and cooling systems.
It helps the device work in outdoor temperatures as low as-15 °C/-20 °C during heating and-15 °C during cooling operations.
Use a DC dual-rotor compressor for maximum high-speed operation up to 120 rpm to provide the necessary power.
Optimization of compressor operation via vector control and start current is significantly improved compared to previous models. Besides, vibration is a reduction.
A vector control method is a technical way of maximizing control by transforming current waves into a sinusoidal waveform.
* When the outdoor unit install is 30m or higher than the indoor unit, please set SW5-2 upon this PCB controller to "On".
The propeller and the fan engine can separate from the right side of the indoor machine. Maintenance can conduct from the right side or the bottom of the unit.
Drain pump installed with pipe lift of 600mm. The indoor unit has hidden under the ceiling, suitable for luxurious interior space.
When the drain pan is dirty, you can easily check it through this transparent window without having to remove the drain.
When you choose the powerful-Hi mode
Noise level: 100VN (S) AVF2 44dB (A), 125VN (S) AVF 45dB (A), 140VN (S) AVF 47dB (A), 100VN (S) APVF 37dB (A), 125VNAPVF 36dB (A), 140VNAPVF1 38dB (A), 140VNATVF 37dB (A)
Air flow: 100VN (S) VF2 36m3 / min, 125VN (S) VF 39m3 / min, 140VN (S) VF 48m3 / min, 100VN (S) PVF 13m3 / min, 125VNPVF 20m3 / min, 140VNPVF1 24m3 / min, 140VNTVF 13m3 / min
Note:
Parameters are measure under conditions (IOS-T1)
Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. By 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.
* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions
** Indicators only apply when operating one indoor unit
*** Static pressure can change by setting on the controller. The maximum static pressure on "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa
**** If cooling operation carries out when the outdoor temperature is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the low pressure will slip off, and the compressor frequency will increase, which reduces the capacity and can lead to damage.